1.
Reprod Biomed Online ; 48(3): 103643, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262209

RESUMO

RESEARCH QUESTION: Does a commercially available quantitative beta-human chorionic gonadotrophin (BHCG) point of care testing (POCT) device improve workflow management in early pregnancy by performing comparably to gold standard laboratory methods, and is the performance of a validated pregnancy of unknown location (PUL) triage strategy maintained using POCT BHCG results? DESIGN: Women classified with a PUL between 2018 and 2021 at three early pregnancy units were included. The linear relationship of untreated whole-blood POCT and serum laboratory BHCG values was defined using coefficients and regression. Paired serial BHCG values were then incorporated into the validated M6 multinomial logistic regression model to stratify the PUL as at high risk or at low risk of clinical complications. The sensitivity and negative predictive value were assessed. The timings required for equivocal POCT and laboratory care pathways were compared. RESULTS: A total of 462 PUL were included. The discrepancy between 571 laboratory and POCT BHCG values was -5.2% (-6.2 IU/l), with a correlation coefficient of 0.96. The 133 PUL with paired 0 and 48 h BHCG values were compared using the M6 model. The sensitivity for high-risk outcomes (96.2%) and negative predictive values (98.5%) was excellent for both. Sample receipt and laboratory processing took 135 min (421 timings), compared with 12 min (91 timings) when using POCT (P < 0.0001). CONCLUSIONS: POCT BHCG values correlated well with laboratory testing measurements. The M6 model retained its performance when using POCT BHCG values. Using the model with POCT may improve workflow and patient care without compromising on effective PUL triage.


Assuntos
Gravidez Ectópica , Gravidez , Humanos , Feminino , Gonadotropina Coriônica , Gonadotropina Coriônica Humana Subunidade beta , Valor Preditivo dos Testes , Modelos Logísticos
2.
Clin Chem Lab Med ; 62(4): 664-673, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37886834

RESUMO

OBJECTIVES: Quantitative human chorionic gonadotropin (hCG) measurements are used to manage women classified with a pregnancy of unknown location (PUL). Two point of care testing (POCT) devices that quantify hCG are commercially available. We verified the i-STAT 1 (Abbott) and the AQT 90 FLEX (Radiometer) prior to use in PUL triage. METHODS: Tests for precision, external quality assurance (EQA), correlation, hook effect and recovery were undertaken alongside a POCT usability assessment during this prospective multi-center verification. RESULTS: Coefficients of variation ranged between 4.0 and 5.1 % for the three i-STAT 1 internal quality control (IQC) solutions and between 6.8 and 7.3 % for the two AQT IQC solutions. Symmetric differences in POCT EQA results when compared with laboratory and EQA stock values ranged between 3.2 and 24.5 % for the i-STAT 1 and between 3.3 and 36.9 % for the AQT. Correlation coefficients (i-STAT 1: 0.96, AQT: 0.99) and goodness of fit curves (i-STAT 1: 0.92, AQT: 0.99) were excellent when using suitable whole blood samples. An hCG hook effect was noted with the i-STAT 1 between 572,194 and 799,089 IU/L, lower than the hook effect noted with the AQT, which was between 799,089 and 1,619,309 IU/L. When hematocrit concentration was considered in sample types validated for use with each device, hCG recovery was 108 % with the i-STAT 1 and 98 % with the AQT. The i-STAT 1 scored lower on usability overall (90/130) than the AQT (121/130, p<0.001, Mann-Whitney). CONCLUSIONS: Both hCG POCT devices were verified for use in clinical practice. Practical factors must also be considered when choosing which device to use in each unit.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Interface Usuário-Computador , Gravidez , Humanos , Feminino , Estudos Prospectivos , Gonadotropina Coriônica , Testes Imediatos